The following table describes the settings for HTTP Conference Protocol Providers.
|
Setting |
Description |
|
Name |
Name of the service provider. |
|
Description |
Description of the provider. |
|
Maximum Retries |
Number of times to resend a notification before potentially using an alternate service provider; allowable values are from 0 to 10. (Note that some providers may have separate retry logic; for example, even if you set Maximum Retries to 0, the provider may run through its own retry paradigm. Further, be aware that increasing Maximum Retries by one increment may result in more than one retry, as the provider will still carry out its retry logic based on the nature of the previous call failure.) |
|
Retry Interval |
Amount of time in seconds to wait between retries. |
|
Maximum Session Size |
Number of notifications per connection/session. |
|
API URL |
URL to which the Device Engine initially submits (e.g., http://webapi.somecompany.com: 8080). |
|
Username |
Typically, the username supplied by the web API provider; required if the URL uses HTTP authentication. |
|
Password |
Typically, the password supplied by the web API provider; required if the URL uses HTTP authentication. |
|
Response URL |
Web server URL to which the Device Engine forwards the web API's response from the initial submission (e.g., http://yourwebserver/processResponse.jsp). |
| Request Parameters | This area displays an editable list of HTTP request parameters available to this provider. This list is typically specified by the web API. Click Add New Name/Value Pair to create a new request parameter, and then specify a Name and Value in the related fields. To remove a request parameter, select the related check box and then click Remove Selected Name/Value Pair. |